Collections

Kitchens Bath vanities Closets & wardrobes Mudroom & pantry Laundry rooms Home office Stainless steel Lacquered fronts Veneer & oak Oakline Flatstone Fluted

Projects

All projects

Solutions

How we work Cabinet options OEM / ODM Commercial & hospitality Dealers & wholesale

By market

United States Australia Africa Canada United Kingdom Saudi Arabia

By project

Apartments & multi-family Hotels & hospitality Villas & whole-home Importers & trade buyers

Company

About Factory & capacity Quality & warranty Blog

Guides

Importing & compliance Sourcing & QC Installation guide Contact Get a quote WhatsApp +86 177 0868 3991

Closet systems · North American standard

North-American-standard closet systems, built to US dimensions

Every dimension, hole spacing and load rating on one page, specified rather than described. If a supplier will not publish these numbers, two quotes for the same room cannot be compared - and the difference between the two systems that decide how a closet works is smaller than most people assume.

Walk-in wardrobe with glass uppers, lit shelving and a full-length hanging run
A walk-in is the same carcass as a reach-in, repeated. Which is why the numbers below are the whole product.

The dimensions we build to

North American rooms have a shape, and the shape decides the numbers. These are the dimensions that answer almost every floor plan we are sent, published so a drawing can be checked against them before anyone asks us.

DimensionSpecificationWhy that number
Standard depth24 in (610 mm)What a full-length garment on a hanger needs in front of the rail
Shallow depth14 in (356 mm)Short hang, folded storage and shoe shelves only; takes about 40% less floor depth
Garment rail, single hang66 in (1,676 mm)Fits full-length garments without the hem touching the floor
Garment rail, double hang40 in + 80 in (1,016 + 2,032 mm)Upper tier for folded items, lower tier for full length
Minimum clear aisle36 in (914 mm)Two people pass; a drawer opens without hitting them
Island clearance36 in (914 mm) on every sideBelow this the island reads as dead space rather than storage
Standard case height72 in (1,830 mm)Consistent reveal across a run; repeats vertically without cutting
Top shelf84-96 in (2,134-2,438 mm)Reachable height for seasonal storage without a step
Shoe shelf spacing7-8 in (178-203 mm)Shoe height plus toe clearance, so pairs face forward
Return wall depth12 in (305 mm) maximumBeyond this the return reads as a second, shallower closet
Most common footprint7 ft x 7 ft to 9 ft x 10 ftA double-sided run needs about 7 ft of width before opposing doors collide

One point of honest disagreement. Published minimum sizes for a workable walk-in range from 4 ft x 4 ft upward, and the reason is that "workable" is doing the work: a 4 ft square fits a single-sided run with no island and no opposing drawers. Our own minimum is stated by layout rather than as a single figure, and the dimensions guide sets out which layout each of those numbers actually serves.

The board, the edge, and why the edge matters more

Our standard carcass is 18 mm - three-quarters of an inch - E0-grade plywood, with ENF available on request. Every cut edge is banded at 2 mm with PVB hot-melt, and door fronts carry a 2 mm exposed edge. The back panel is 9 mm in the same board.

The finish is the layer everybody photographs. The edge is the layer that decides whether the closet still looks right in year eight, because the band is the only membrane between the core and the air, and every door cycle flexes the panel slightly at the joint. We band internal panels to the same 2 mm rather than downgrading the hidden ones to save cost - on a multi-unit run where every panel is identical, removing that site decision is worth more than the millimetre. The full material comparison covers where melamine, plywood and veneer each fail, and why a compromised edge in plywood is a repairable cosmetic problem while the same compromise in particleboard is a swelling core.

32 mm system holes, and the other system nobody mentions

This is the detail almost no North American closet manufacturer publishes, and it is the one that most often goes wrong on site.

SystemHole centresBoreFront setbackWhere it is standard
32 mm pattern32 mm (1-1/4 in)5 mm37 mm from front edgeEuropean frameless cabinetry, and our standard
1 inch system25.4 mm (1 in exact)1/4 in pin1/2 in from front edgeNorth American face-frame cabinetry

Both are legitimate systems and both appear in good product. The problem is only mixing them: the two are close enough that a catalogue photograph will not reveal the difference, and far enough apart that shelf pins from one will not seat in the other. A carcass drilled to 32 mm and fitted with 1 inch shelf supports fails at the first shelf, not at the first inspection.

Our 32 mm pattern is CNC-drilled with a 5 mm bore and a 37 mm front setback, which is why a shelf moves in clean 32 mm steps rather than the uneven increments of an older pattern. Every unit leaves the factory with the hole centres printed on the specification sheet, so a field installer can verify a cabinet before the first shelf goes in. The hardware guide covers what sits in those holes and how each rating should be read.

Hardware, and what the rating actually means

Closet hardware is where the specification most often goes vague, because each manufacturer names its rating differently. Three conventions are in current use and they carry different obligations.

ConventionWho uses itWhat it means
Weight recommendationElfa and component-system suppliersA suggested figure for guidance; the supplier does not warrant against it
Load capacity / ratingBlum, HettichA tested figure under defined conditions, warranted by the maker
Maximum load, not to be exceededClosetMaid and several system brandsAn explicit ceiling; exceeding it voids the warranty

On our program: Blum soft-close hinges rated to 50,000 open-close cycles, and Blum TANDEM full-extension runners at 35-45 kg per pair. A cycle rating is a rating rather than a lifespan promise - in a daily-use master bedroom, 50,000 operations is roughly fifteen years. Shelf load is 65 lb per linear foot, garment rail 15 lb per linear foot, both evenly distributed; the distribution assumption is the operative part, because a shelf carrying a stack at one end behaves differently from the same shelf carrying it spread along its length. Wardrobe lifts are gas-strut, rated to 10 kg of garment load with a minimum rail load of 4 kg.

Three build levels, separated by specification

The levels are separated by what is in them, not by what they cost. That is deliberate: it is the only way to offer a tier structure without publishing a price list, and it is the structure a developer's Good-Better-Best upgrade package already speaks.

GoodBetterBest
Carcass18 mm E0 plywood18 mm E0 plywood, ENF on request18 mm E0 plywood, ENF on request
Edge banding2 mm PVB, every cut edge2 mm PVB + 2 mm exposed edge on door fronts2 mm PVB, laser-sealed visible edges
HingesBlum soft-close, 50,000 cyclesBlum soft-close, 50,000 cyclesBlum soft-close, 50,000 cycles
RunnersFull-extension, 35 kg per pairBlum TANDEM full-extension, 35-45 kg per pairHettich WingLine, 40-50 kg per pair
DoorsOpen shelvingOptional flat panelLow-iron glass with aluminium frame
Moving fittingsFixed railsValet rod, corner rodGas-strut wardrobe lift, rated 10 kg
SuitsMulti-unit residential, apartment runsDeveloper Good/Better/Best middle tier, hospitalityPrimary suites, retail and hospitality display

All three levels share the same 32 mm system holes, so a house can mix levels room by room without the hardware changing underneath. What changes between levels is the finish, the runners, the doors and the moving fittings - never the hole spacing, and never the carcass thickness.

Lead time, and what happens inside it

12-16 days of factory production from approved shop drawings. Inside that window: CNC cutting, banding on every cut edge, cycle-testing the hinges and runners and any wardrobe lifts, trial assembly of the unit, and three photographic checkpoints before the crate is sealed. What leaves the factory is flat-packed, numbered, corner-protected and shipped with a per-room install manual.

What sits outside that window is transit, which depends on destination and routing rather than on the closet. We do not quote a door-to-door number here, because the honest answer is that it changes with port, season and carrier - the imported-versus-domestic guide explains how both sides of that calculation work and where the fixed costs actually sit.

Twelve questions to ask any closet supplier

If you take nothing else from this page, take this. Twelve questions, in the order that eliminates the most ambiguity first.

  1. What is the hole spacing on the carcass, in millimetres?
  2. What is the board thickness, and what is its emissions class?
  3. What is on the cut edge, and how thick - including internal panels?
  4. What is the back panel, and how thick?
  5. What is the hinge cycle rating?
  6. Is the drawer rating per pair or per runner?
  7. What is the shelf rating, and is it per linear foot or per shelf?
  8. What is the garment rail rating?
  9. Is hardware itemised on its own line, or folded into a per-foot figure?
  10. Which items are exclusions - inserts, glass doors, lifts, lighting?
  11. Does the shipment carry a numbered install manual?
  12. What is the production lead time, and what starts it?

Question 1 and question 9 are the two that most often change what a quote actually means. A supplier who answers both plainly is a supplier whose document can be compared against anyone else's.

FAQ

Is 24 inches the standard depth? Can we go shallower?
24 inches - 610 mm - is our standard depth because it is what a full-length garment on a hanger needs in front of the rail. If your runs are all short hang, folded storage or shoe shelves, a 14 inch - 356 mm - carcass is available and takes roughly 40 percent less floor depth for the same wall length. What does not work well below 14 inches is a double hang, because the two tiers need clearance in front of each other. The decision is made per room rather than per house, and it belongs on the drawing rather than in a conversation after ordering.
Can a 32 mm drilled cabinet take 1 inch hardware?
No, and this is the single most common field error we are asked about. The two systems are close enough to look interchangeable in a catalogue and far enough apart that shelf pins from one will not seat in the other. 32 mm pattern means holes at 32 mm centres with a 5 mm bore and a 37 mm front setback. The 1 inch system means holes at 25.4 mm - one inch exactly - with a quarter-inch pin and a different front reference. Both are legitimate. Mixing a 32 mm carcass with 1 inch shelf supports is not, and it fails in a way that is only discovered when the first shelf goes in.
Why does the edge banding matter more than the finish?
Because the finish is a photograph and the edge is a membrane. The band on a panel is the only thing between the core and the air, and every time a door opens or a drawer pulls out the panel flexes slightly at the joint. On a particleboard core a breached band lets moisture in and the core swells permanently. We band every cut edge at 2 mm PVB hot-melt - including internal panels, not only the visible ones - because on a multi-unit run where the panels are identical, removing an entire class of site decision is worth more than the millimetre costs. A melamine surface with 2 mm banding and good hardware outlasts a veneer surface with 1 mm banding and cheap runners.
What is the difference between your three build levels?
The levels are separated by specification rather than by price. Good uses 18 mm E0 plywood with 2 mm PVB banding throughout and Blum soft-close hinges with full-extension runners at 35 kg per pair - sized for multi-unit residential and apartment work. Better keeps the same carcass and banding and moves to Blum TANDEM runners at 35-45 kg with 2 mm exposed edge on door fronts, which is the level most Good-Better-Best developer packages land on. Best adds low-iron glass doors and moves hardware to Hettich WingLine plus a gas-strut wardrobe lift. All three ship with the same 32 mm system holes, so a room can mix levels across a house without the hardware changing underneath.
Is the closet height 72 inches or floor-to-ceiling?
72 inches - 1,830 mm - is the standard case height, and it is the height that produces a consistent reveal across a multi-unit run and lets a run repeat vertically without cutting. Floor-to-ceiling is available on request and needs two things specified with it: a scribe allowance, because a ceiling that is not flat needs the top panel cut to fit rather than to a square; and a decision about what happens at the top, since the storage gained above the standard height is storage nobody can reach without a step. For that reason we will draw the upper section as a shallow bulkhead rather than as full-depth shelving.
What does the 12-16 day lead time cover?
It covers factory production from approved shop drawings, not the ocean leg. Inside those 12-16 days we CNC the panels, band every cut edge, cycle-test the hinges, runners and any wardrobe lifts, run a trial assembly on the unit, and photograph it at three points before the crate is sealed. After crating the pieces ship flat-packed and numbered with a per-room install manual. What varies outside that window is transit, which is a function of destination and routing rather than of the closet itself - and if you want a number on the whole door-to-door path rather than just the factory span, the imported-versus-domestic guide sets out how both sides of that calculation work.
How is this different from buying from a North American closet brand?
Three things, stated plainly. First, the economics: a North American brand carries showroom overhead, a designer salary and a second margin layer between the factory and your invoice, and a factory-direct program does not. Second, the specification transparency - on this page every dimension, rating and hole spacing is published, which is not the norm for consumer closet brands. Third, the control: you can change a run, add an insert, or run forty units on the same drawing with the same finish batch, because the production line is yours to schedule. What you give up is a local showroom to visit and a crew down the road, and for a single residential room that trade is often not worth it.

The full specification

This table is the same document that travels with your shop drawings, which is the version any supplier - including us - can be held to.

The Beverly whole-house program ran on this sheet - every room on one finish decision, with one revision history the dealer and the factory both signed off.

ItemSpecification
Carcass18 mm (3/4 in) E0-grade plywood, ENF on request
Edge banding2 mm PVB hot-melt on every cut edge
Back panel9 mm, same board
System holes32 mm centres, 5 mm bore, 37 mm front setback
Standard depth24 in (610 mm); 14 in (356 mm) option
Garment rail66 in single hang; 40 in + 80 in double hang
Minimum clear aisle36 in (914 mm)
Case height72 in (1,830 mm) standard; floor-to-ceiling on request
HingesBlum soft-close, rated to 50,000 open-close cycles
DrawersBlum TANDEM full-extension runners, 35-45 kg per pair
Shelf rating65 lb per linear foot, evenly distributed
Garment rail rating15 lb per linear foot, evenly distributed
Wardrobe liftGas strut, rated 10 kg; minimum rail load 4 kg
Lead time12-16 days factory production

Units are given the way North American cabinetry states them, with the metric equivalent alongside. Where a supplier quotes only in one system, ask which one and how they convert - it is a small question that surfaces a surprising number of errors.

Two guides sit behind this page if you are still specifying: every closet hardware type, named and rated, and the dimensions that make a layout workable. The wider closet program covers the pieces that sit outside a walk-in - wardrobe walls, jewellery displays and dressing rooms.

The short version

  • 24 in depth, 66 in rails, 36 in clear aisle, 72 in case height, 32 mm system holes. Those are the numbers a drawing can be checked against.
  • Two hole systems exist - 32 mm and 1 inch. A carcass drilled to one and fitted with hardware built for the other fails at the first shelf.
  • Three build levels separated by specification, not price. All three share the same hole spacing and the same 18 mm carcass.
  • Hardware itemised on its own line is the difference between a document you can compare and one you can only accept.